Cold air from the vents when the heat is on usually comes down to a handful of causes. A few you can check in five minutes.
Check these first
- Fan set to On. If the thermostat fan is on "On" instead of "Auto," the blower runs between heating cycles and pushes room-temperature air. Switch it to Auto.
- Furnace still warming up. Many furnaces wait 30 to 90 seconds after lighting before the blower starts, and a short puff of cool air is normal.
- Dirty filter. A clogged filter makes the furnace overheat, and a safety switch shuts the burners off while the fan keeps running. Replace it.
- Gas supply. Make sure the gas valve at the furnace is open, and that other gas appliances work.
Common causes a technician fixes
- A dirty flame sensor, which lets the burners light for a few seconds and then shuts them off.
- A worn hot-surface igniter that no longer glows hot enough to light the gas.
- A clogged condensate drain on high-efficiency furnaces, which trips a safety switch.
- A failed pressure switch or inducer motor.
If you have a heat pump rather than a gas furnace, cool-feeling air can be normal. See furnace and heat pump repair for the difference.
Smell gas? Leave the house and call your gas company or 911 from outside.